jm + esd   1

"One of our office chairs turns off monitors"
Crappy unshielded display cables are prone to electrostatic discharges from gas-lift office chairs...

"we have also seen this issue connected to gas lift office chairs. When people stand or sit on gas lift chairs, they can generate an EMI spike which is picked up on the video cables, causing a loss of sync. If you have users complaining about displays randomly flickering it could actually be connected to people sitting on gas lift chairs. Again swapping video cables, especially for ones with magnetic ferrite ring on the cable, can eliminate this problem."
chairs  furniture  funny  hardware  emi  esd  monitors  twitter  video 
17 days ago by jm